Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
Pract Lab Med ; 31: e00289, 2022 Aug.
Article in English | MEDLINE | ID: covidwho-2245828

ABSTRACT

Background: The 2019 novel coronavirus infectious disease (COVID-19) pandemic resulted in a surge of assays aimed at detecting severe acute respiratory syndrome (SARS) - coronavirus (CoV) - 2 infection and prior exposure. Although both molecular and antigen testing have clearly defined uses, the utility of serology remains uncertain and is presently not recommended for assessing immunity. Methods: We conducted a pragmatic, observational study evaluating four commercially available emergency use authorized laboratory-based COVID-19 serology assays (Assays A-D). Remnant samples from hospitalized, and non-hospitalized SARS-CoV-2 PCR positive patients, as well as vaccinated and unvaccinated individuals were collected and tested. Positive percent agreement (PPA) and negative percent agreement (NPA) were calculated. Antibody concentrations were compared across the platforms and populations. Results: A total of 588 remnant samples derived from 500 patients were tested. PPA at 5-12 weeks post-PCR positive results for Assays A-D was 98.3, 97.4, 99.2, and 95.8% respectively. NPA was 100% across all platforms. Mean antibody concentrations at 2-4 weeks post-PCR positive result were significantly higher in hospitalized versus non-hospitalized patients, respectively, for Assay A (131.8 [101.7] vs. 95.6 [100.3] AU/mL, P < 0.001), B (61.7 [62.4] vs. 38.1 [40.5] AU/mL, P < 0.001), and C (157.6 [105.3] vs. 133.3 [100.7] AU/mL, P < 0.001). For individuals receiving two vaccine doses mean antibody concentrations were respectively 169.6 (104.4), 27.3 (50.8), 189.6 (120.9), 21.19 (13.1) AU/mL for Assays A-D. Conclusions: Overall, PPA and NPA differed across the four assays. Assays A and C produced higher PPA and NPA and detected larger concentrations of antibodies following vaccination.

2.
J Clin Microbiol ; 59(2)2021 01 21.
Article in English | MEDLINE | ID: covidwho-1042274

ABSTRACT

Highly accurate testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) at the point of care (POC) is an unmet diagnostic need in emergency care and time-sensitive outpatient care settings. Reverse transcription-PCR (RT-PCR) technology is the gold standard for SARS-CoV-2 diagnostics. We performed a multisite U.S. study comparing the clinical performance of the first U.S. Food and Drug Administration (FDA)-authorized POC RT-PCR for detection of SARS-CoV-2 in 20 min, the cobas Liat SARS-CoV-2 and influenza A/B nucleic acid test, to the most widely used RT-PCR laboratory test, the cobas 68/8800 SARS-CoV-2 test. Clinical nasopharyngeal swab specimens from 444 patients with 357 evaluable specimens at five U.S. clinical laboratories were enrolled from 21 September 2020 to 23 October 2020. The overall agreement between the Liat and 68/8800 systems for SARS-CoV-2 diagnostics was 98.6% (352/357). Using Liat, positive percent agreement for SARS-CoV-2 was 100% (162/162) and the negative percent agreement was 97.4% (190/195). The Liat is an RT-PCR POC test that provides highly accurate SARS-CoV-2 results in 20 min with performance equivalent to that of high-throughput laboratory molecular testing. Rapid RT-PCR testing at the POC can enable more timely infection control and individual care decisions for coronavirus disease 2019.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , Point-of-Care Systems , SARS-CoV-2/isolation & purification , COVID-19 Nucleic Acid Testing/instrumentation , Humans , Nasopharynx/virology , SARS-CoV-2/genetics , Time Factors , United States
SELECTION OF CITATIONS
SEARCH DETAIL